skip to primary navigation skip to content

CBSU bibliography search


To request a reprint of a CBSU publication, please click here to send us an email (reprints may not be available for all publications)

The upper limit of temporal pitch for cochlear-implant listeners: stimulus duration, conditioner pulses, and the number of electrodes stimulated.
Authors:
CARLYON, R.P., DEEKS, J.M., McKay, C.M.
Reference:
The Journal of the Acoustical Society of America, 127(3), 1469-78
Year of publication:
2010
CBU number:
7278
Abstract:
Three experiments studied discrimination of changes in the rate of electrical pulse trains by cochlear-implant (CI) users and investigated the effect of manipulations that would be expected to substantially affect the pattern of auditory nerve (AN) activity. Experiment 1 used single-electrode stimulation and tested discrimination at baseline rates between 100 and 500 pps. Performance was generally similar for stimulus durations of 200 and 800 ms, and, for the longer duration, for stimuli that were gated on abruptly or with 300-ms ramps. Experiment 2 used a similar procedure and found that no substantial benefit was obtained by the addition of background 5000-pps "conditioning" pulses. Experiment 3 used a pitch-ranking procedure and found that the range of rates over which pitch increased with increasing rate was not greater for multiple-electrode than for single-electrode stimulation. The results indicate that the limitation on pulse-rate discrimination by CI users, at high baseline rates, is not specific to a particular temporal pattern of the AN response.